REX NORDIC BX E-GENERATORS
SAVE UP TO 80% ON
DIESEL GENERATOR OPERATING COSTS
THE FUTURE OF EMISSION-FREE POWER FOR PROFESSIONALS
The Rex Nordic BX e-GENERATOR is an excellent choice for construction and infrastructure sites, events, agriculture, and other demanding applications where a reliable, efficient, and environmentally friendly energy storage and distribution solution is needed.
WHAT IS THE REX NORDIC BX E-GENERATOR?
- The BX e-GENERATORS is an advanced portable and emission-free energy solution for situations where electricity is limited or there is no access to a power grid.
- The BX e-GENERATOR stores and distributes electricity as an energy buffer for various work environments as needed.
- Its capacity ranges from 6 kWh up to 72 kWh.If more capacity is needed, BX e-GENERATORS can be connected in series (daisy chain).
- The BX e-GENERATOR can be used independently or in hybrid mode, for example, with a diesel generator.
- The BX e-GENERATORS supports charging via the power grid, diesel generators, or solar panels

HOW DOES THE REX NORDIC BX e-GENERATOR WORK?
- Acts as an energy buffer to achieve higher power outputs
- Charges via solar panels, the power grid, or a diesel generator
- Intelligent automation always selects the most cost-effective charging option
- Plug-and-play – does not require expensive installations
- PowerBoost (peak shaving)– High power peak, up to 3 times the nominal power for 5 seconds
- Provides instantaneous and uninterrupted power supply
- Monitor BX operations via a portal or app
- Controls the diesel generator On/Off
- BX e-Generators can be connected in series
- saavuttamiseksi
SAVE 80% OF DIESEL GENERATOR OPERATING TIME
- Fuel savings up to 80%!
- Reduces CO2 emissions by up to 80%
- The BX e-GENERATOR automatically controls the diesel generator
- The diesel generator’s maintenance costs decrease as runtime is reduced
- Allows the use of a smaller diesel generator in applications with variable power demands
MARKET’S SAFEST BATTERY TECHNOLOGY
- The safest battery technology on the market!
- Batteries are 99% recyclable, no hazardous waste
- Safe to use even in underground spaces and tunnels
- No ADR permits required for transport (UN3536 and UN3481)
– also suitable for sea and air freight - Reliable operation in extreme conditions
WHY CHOOSE REX NORDIC BX e-GENERATOR?
-
3-in-1 Charging Options
Can charge from solar panels, diesel generators, or the grid. The smart system always selects the most economical and environmentally friendly charging method.
-
Power Boost -functionality
Enables the generation of high peak power as needed, increasing flexibility, especially in dynamic work environments.
-
Safe battery technology
We use the safest battery technology on the market. No ADR permits are required for transportation.
-
Fuel consumption reduction of up to 80%
Decreases diesel generator usage, leading to lower fuel costs and maintenance needs.
-
Savings on electrical connections.
You don't need expensive electrical connection upgrades to meet high power demands.
-
Remotely manageable
Remote connectivity enables monitoring and management from a distance, enhancing usability and safety.
-
99% recyclable battery technology.
An environmentally friendly and responsible choice that reduces environmental impact.
-
IP54-suojaus
Kestää pölyä ja vettä, mahdollistaen toiminnan haastavissa olosuhteissa.
-
Valmistettu EU:ssa
Manufactured in the EU.
-
Plug and Play
No complex installation required – simply plug in the device and start using it.
-
Easily portable
Forklift handling or lifting lugs enable the unit to be moved from one location to another.
-
7 models
The widest selection on the market. A unified user interface. Easy training and deployment, even for large teams.
Which Rex Nordic BX e-Generator Suits Your Needs?
Available models range from 6 kWh to 72 kWh, suitable for various applications.
BX-6
Continuous Power VA 25c 4000 |
Peak Power VA 25c 10000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 600 x 900 x 700 |
Name | Value |
---|---|
Frame Model | A |
Continuous Power VA 25c | 4000 |
Peak Power VA 25c | 10000 |
Output Voltage AC | 1 AC 230V |
Input Current Max. AC | 40A 1phase |
Maximum Output Current (with external AC power supply) | 13A (63A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | 16A, 1phase 30 mA Fi |
Available Battery Capacity kWh | 6 |
Input Connector | CEE 16A |
Output Connector A | Schuko 16A |
Output Connector B | Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 600 x 900 x 700 |
Weight (kg) | 360 |
Solar Power Connector | MPPT 4 kW |
BX-12
Continuous Power VA 25c 12000 |
Peak Power VA 25c 30000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 800 x 1200 x 1690 |
Name | Value |
---|---|
Frame Model | B |
Continuous Power VA 25c | 12000 |
Peak Power VA 25c | 30000 |
Output Voltage AC | 3 AC 230V / 400V |
Input Current Max. AC | 50A 3phase |
Maximum Output Current (with external AC power supply) | 39A (89A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | o.100mA FI |
Available Battery Capacity kWh | 12 |
Input Connector | CEE 32A 3phase |
Output Connector A | 3 x Schuko 16A |
Output Connector B | Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 800 x 1200 x 1690 |
Weight (kg) | 750 |
Solar Power Connector | MPPT 5,8kW – 58kW |
BX-18

Continuous Power VA 25c 19500 |
Peak Power VA 25c 48000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 800 x 1800 x 1690 |
Name | Value |
---|---|
Frame Model | C |
Continuous Power VA 25c | 19500 |
Peak Power VA 25c | 48000 |
Output Voltage AC | 3 AC 230V / 400V |
Input Current Max. AC | 100A 3phase |
Maximum Output Current (with external AC power supply) | 63A (363A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | o.300mA FI |
Available Battery Capacity kWh | 18 |
Input Connector | 63 A Option: CEE 125A 3phase |
Output Connector A | 63 A Option: CEE 125A 3phase |
Output Connector B | 3 x Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 800 x 1800 x 1690 |
Weight (kg) | 1230 |
Solar Power Connector | MPPT 5,8kW – 58kW |
BX-24

Continuous Power VA 25c 24000 |
Peak Power VA 25c 75000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 800 x 1800 x 1690 |
BX-36

Continuous Power VA 25c 36000 |
Peak Power VA 25c 75000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 1270 x 2490 x 2250 |
Name | Value |
---|---|
Frame Model | D |
Continuous Power VA 25c | 36000 |
Peak Power VA 25c | 75000 |
Output Voltage AC | 3 AC 230V / 400V |
Input Current Max. AC | 100A 3phase |
Maximum Output Current (with external AC power supply) | 109A (409A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | Isowächter o.300mA FI |
Available Battery Capacity kWh | 36 |
Input Connector | 63 A Option: CEE 125A 3phase |
Output Connector A | 63 A Option: CEE 125A 3phase |
Output Connector B | 3 x Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 1270 x 2490 x 2250 |
Weight (kg) | 2035 |
Solar Power Connector | MPPT 5,8kW – 58kW |
BX-48

Continuous Power VA 25c 48000 |
Peak Power VA 25c 120000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 1270 x 2490 x 2250 |
Name | Value |
---|---|
Frame Model | E |
Continuous Power VA 25c | 48000 |
Peak Power VA 25c | 120000 |
Output Voltage AC | 3 AC 230V / 400V |
Input Current Max. AC | 2*100A 3phase |
Maximum Output Current (with external AC power supply) | 156A (756A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | Isowächter o.300mA FI |
Available Battery Capacity kWh | 48 |
Input Connector | CEE 125A 3phase CEE 63A 3phase |
Output Connector A | CEE 125A 3phase CEE 63A 3phase |
Output Connector B | 3 x Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 1270 x 2490 x 2250 |
Weight (kg) | 3000 |
Solar Power Connector | MPPT 5,8kW – 58kW |
BX-72

Continuous Power VA 25c 72000 |
Peak Power VA 25c 150000 |
Charging Time 2,5h |
Dimensions W x L x H mm: 1270 x 2490 x 2250 |
Name | Value |
---|---|
Frame Model | E |
Continuous Power VA 25c | 72000 |
Peak Power VA 25c | 150000 |
Output Voltage AC | 3 AC 230V / 400V |
Input Current Max. AC | 3*100A 3phase |
Maximum Output Current (with external AC power supply) | 218A (818A) |
Protection Functions | Overload, overheating, short circuit, depleted battery |
Grounding Protection | Isowächter o.300mA FI |
Available Battery Capacity kWh | 72 |
Input Connector | CEE 125A 3phase CEE 63A 3phase |
Output Connector A | CEE 125A 3phase CEE 63A 3phase |
Output Connector B | 3 x Schuko 16A |
Charging Time | 2,5 Hours |
Auxiliary Contact (remote start for diesel generator) | Harting |
Battery Monitoring | LED |
IP Class | IP54 |
Operating Temperature Range | ‘-15c – +45c |
Dimensions W x L x H mm | 1270 x 2490 x 2250 |
Weight (kg) | 4070 |
Solar Power Connector | MPPT 5,8kW – 58kW |
Greater capacity can be provided by serializing BX units.
EXAMPLES OF USE CASES

CONSTRUCTION SITES

TUNNELS AND MINES

EVENTS

AGRICULTURE AND INDUSTRY

REMOTE AREAS